中国组织工程研究 ›› 2011, Vol. 15 ›› Issue (47): 8837-8841.doi: 10.3969/j.issn.1673-8225.2011.47.024

• 材料生物相容性 material biocompatibility • 上一篇    下一篇

微透析活体采样比较静脉和玻璃体内注射万古霉素在兔玻璃体内的通透性

王亚玲1,于海涛1,陈晓隆2   

  1. 1青岛市市立医院眼科,山东省青岛市  266001
    2中国医科大学盛京医院眼科,辽宁省沈阳市  110006
  • 收稿日期:2011-05-02 修回日期:2011-07-11 出版日期:2011-11-19 发布日期:2011-11-19
  • 作者简介:王亚玲★,女,1968年生,山东省潍坊市人,2004年中国医科大学毕业,硕士,主治医师,主要从事微透析技术在眼科的应用研究。 wyl8226@ 163.com

Microdialysis in a conscious rabbit ocular posterior segment and the pharmacokinetics study of vancomycin after intravenous and intravitreal administration

Wang Ya-ling1, Yu Hai-tao1, Chen Xiao-long2   

  1. 1Department of Ophthalmology, Qingdao Municipal Hospital, Qingdao  266001 Shandong Province, China
    2Department of Ophthalmology, Shengjing Hospital of China Medical University, Shenyang 110006, Liaoning Province, China
  • Received:2011-05-02 Revised:2011-07-11 Online:2011-11-19 Published:2011-11-19
  • About author:Wang Ya-ling★, Master, Attending physician, Department of Ophthalmology, Qingdao Municipal Hospital, Qingdao 266001 Shandong Province, China wyl8226@163.com

摘要:

背景:目前眼部药代动力学研究的人体及动物实验采样方法,均是在体外进行,存在诸多的弊端。
目的:利用微透析活体采样技术,建立眼后节清醒动物药代动力学模型,比较静脉注射和玻璃体内注射万古霉素在兔玻璃体内的通透性。
方法:纳入15只兔,制备眼内炎模型。将微透析探针植入清醒兔眼玻璃体内24 h后,随机分成3组,即静脉注射组、玻璃体内注射组及静脉注射+玻璃体内注射组,分别根据不同的给药方式注射万古霉素。高效液相色谱-紫外检测法连续检测兔眼玻璃体万古霉素的浓度,3p97药代动力学软件拟合药动学参数。
结果与结论:静脉注射组兔眼玻璃体内的药物浓度较低,达不到有效的治疗效果;玻璃体内注射组及静脉注射+玻璃体内注射组兔眼给药后72 h,玻璃体内万古霉素的浓度均高于有效治疗浓度。提示微透析方法联合高效液相色谱-紫外检测法,可以连续、在线、活体检测清醒动物玻璃体内药物浓度;单次静脉注射万古霉素后,玻璃体内不能达到有效治疗剂量。

关键词: 微透析, 高效液相色谱法, 静脉注射, 玻璃体, 万古霉素

Abstract:

BACKGROUND: Currently, in the pharmacokinetic studies of the eye, the sample selection is often carried out in vitro, and there are many disadvantages.
OBJECTIVE: To develop a novel ocular microdialysis technology in conscious rabbit eyes, and to compare the difference of the pharmacokinetics of vancomycin after intravenous and intravitreal administration.
METHODS: Fifteen healthy and mature rabbits were used to prepare endophthalmitis models and were randomly divided into three groups (intravenous administration, intravitreal administration and intravenous+intravitreal administration) at 24 hours after microdialysis probe was implanted. Vitreous vancomycin concentration was detected by high performance liquid chromatography-ultraviolet (HPLC-UV).
RESULTS AND CONCLUSION: The vancomycin concentration in the intravenous administration group was much lower than the other two groups. At 72 hours after administration, the vancomycin concentrations in the intravitreal administration and intravenous+intravitreal administration groups reached a therapeutic concentration. It is indicated that microdialysis combined with HPLC-UV can continuously and in vivo detect the vancomycin concentration in the vitreous body, and single administration of vancomycin cannot reach a therapeutic concentration.

中图分类号: