[1] RAMNEMARK A, NYBERG L, LORENTZON R, et al. Progressive hemiosteoporosis on the paretic side and increased bone mineral density in the nonparetic arm the first year after severe stroke. Osteoporos Int. 1999;9(3):269-275.
[2] RAMNEMARK A. Fractures after Stroke. Osteoporos Int. 1998;8(1):92-95.
[3] RAMNEMARK A, NILSSON M, BORSSEN B, et al. Stroke, a major and increasing risk factor for femoral neck fracture. Stroke. 2000;31(7): 1572-1577.
[4] QUEALLY JM, ABDULKARIM A, MULHALL KJ, et al. Total hip replacement in patients with neurological conditions. J Bone Joint Surg Br. 2009; 91(10):1267-1273.
[5] 李树明,陈晶,宋光泽,等.双动全髋关节置换治疗脑卒中偏瘫侧股骨颈骨折[J].中国矫形外科杂志,2020,28(20):1907-1909.
[6] RYU HG, ROH YJ, OH KJ, et al. Dual Mobility Articulation Total Hip Arthroplasty for Displaced Neck Fracture in Elderly with Neuromuscular Disorder. Injury. 2021;6(52):1480-1486.
[7] 臧加成,王裕民,王敬博,等.合并偏瘫的老年股骨颈骨折全髋关节置换术的早期疗效[J].中华骨科杂志,2017,37(23):1466-1473.
[8] 胥伯勇,郭文涛,穆文博,等.限制性内衬翻修治疗髋关节置换术后反复脱位的7例报道[J].新疆医科大学学报,2018,41(6):697-701.
[9] NIES FD, FIDLER MW. Visual analog scale for the assessment of total hip arthroplasty. J Arthroplasty. 1997;12(4):416-419.
[10] LIN HL, LIN HC, TSENG YF, et al. Hip fracture after first-ever stroke: a population-based study. Acta Neurol Scand. 2015;131(3):158-163.
[11] KOTWAL RS, GANAPATHI M, JOHN A, et al. Outcome of treatment for dislocation after primary total hip replacement. J Bone Joint Surg Br. 2009;91(3):321-326.
[12] GOETZ DD, CAPELLO WN, CALLAGHAN JJ, et al. Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component. A retrospective analysis of fifty-six cases. Joint Surg Am. 1998;80(4):2419-2423.
[13] GOETZ DD, CAPELLO WN, CALLAGHAN JJ, et al. Salvage of total hip instability with a constrained acetabular component. Clin Orthop. 1998; 355(355):171-181.
[14] 廖亮,赵劲民,苏伟,等.全髋与半髋关节置换治疗老年股骨颈骨折的Meta分析[J].中国组织工程研究与临床康复,2010,14(22): 3991-3995.
[15] PHILIPPOT R, MEUCCI JF, BOYERET B, et al. Modern dual-mobility cup implanted with an uncemented stem: about 100 cases with 12-year follow-up. Surg Technol Int. 2013;9(23):208-212.
[16] BOYER B, PHILIPPOT R, GERINGERET J, et al. Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop. 2012;36(3):511-518.
[17] GILL K, WHITEHOUSE SL, HUBBLE MJW, et al. Short-term results with a constrained acetabular liner in patients at high risk of dislocation after primary total hip arthroplasty. Hip Int. 2016;26(6):580-584.
[18] JONES, STEPHEN A. Constrained Acetabular Liners. J Arthroplasty. 2018; 33(5):1331-1336.
[19] MULLEY G, ESPLEY AJ. Hip fracture after hemiplegia. Postgrad Med J. 1979;55(642):264-265.
[20] SHAPIRO GS, WEILAND DE, MARKELET DC, et al. The use of a constrained acetabular component for recurrent dislocation. J Arthroplasty. 2003;18(3):250-258.
[21] SU EP, PELLICCI PM. The role of constrained liners in total hip arthroplasty. Clin Orthop Relat Res. 2004;420:122-129.
[22] SONG JH, KWON WH, OH S, et al. Use of a Constrained Acetabular Liner to Prevent and Treat Recurrent Dislocation after Total Hip Replacement Arthroplasty. Orthopaedic Surg. 2020;6(12):2004-2012.
[23] CLAYTON ML, THIRUPATHI RG. Dislocation following total hip arthroplasty. Clin Orthop. 1983;(177):154-159.
[24] MORREY BF. Instability after Total Hip Arthroplasty. Orthop Clin Nam. 1992;23(2):237-248.
[25] WARSCHAWSKI Y, GARCEAU SP, JOLY DA, et al. The Effect of Femoral Head Size, Neck Length, and Offset on Dislocation Rates of Constrained Acetabular Liners. J Arthroplasty. 2020;36(1):345-348.
[26] JO S, ALMONTE JJ, SIERRA RJ. The Cumulative Risk of Re-dislocation After Revision THA Performed for Instability Increases Close to 35% at 15years. J Arthroplasty. 2015;30(7):1177-1182.
|