中国组织工程研究 ›› 2011, Vol. 15 ›› Issue (35): 6639-6642.doi: 10.3969/j.issn.1673-8225.2011.35.042

• 骨与关节临床实践 clinical practice of the bone and joint • 上一篇    下一篇

老年人膝关节和踝关节位置觉的重测信度

王雪强1,2,郑洁皎2,俞卓伟2,刘  静1,冯  彦1,曾德铭1,陈千红1   

  1. 1上海体育学院,上海市 200438
    2复旦大学附属华东医院,上海市200040
  • 收稿日期:2011-02-17 修回日期:2011-07-13 出版日期:2011-08-27 发布日期:2011-08-27
  • 通讯作者: 郑洁皎,主任医师,复旦大学附属华东医院康复医学科,上海市 200040
  • 作者简介:王雪强★,男,1985年生,江西省南昌市人,汉族,上海体育学院在读硕士,主要从事运动康复的研究。 qiang897@163.com
  • 基金资助:

    上海市科委课题(09411967300)。

Test-retest reliability of joint position in the knee and ankle of older people

Wang Xue-qiang1, 2, Zheng Jie-jiao2, Yu Zhuo-wei2, Liu Jing1, Feng Yan1, Zeng De-ming1, Chen Qian-hong1   

  1. 1Shanghai University of Sport, Shanghai  200438, China
    2Huadong Hospital, Fudan University, Shanghai  200040, China
  • Received:2011-02-17 Revised:2011-07-13 Online:2011-08-27 Published:2011-08-27
  • Contact: Zheng Jie-jiao, Chief physician, Huadong Hospital, Fudan University, Shanghai 200040, China
  • About author:Wang Xue-qiang★, Studying for master’s degree, Shanghai University of Sport, Shanghai 200438, China qiang897@163.com
  • Supported by:

    Shanghai Science and Technology Committee, No. 09411967300*

摘要:

背景:目前国内外关节位置觉的研究主要以青年人为对象,而老年人在不同角度关节位置重现的重测信度研究比较缺乏。
目的:观察老年人膝关节和踝关节在不同角度关节复位测试的重测信度。
方法:在Biodex system 3等速系统上用被动复位测试法测试28名健康老年人的膝、踝关节本体感觉,以被动复位绝对误差角度作为个体位置觉能力优劣的代表。重测信度评价指标为组内相关系数(ICC)。
结果与结论:左右两侧膝关节位置觉测试在不同角度都具有良好的重测信度,ICC值为0.851~0.973;左右两侧踝关节位置觉测试在跖屈与背伸位具有中等以上的重测信度,ICC值为0.742~0.964;左侧踝关节复位的绝对误差角度小于右侧踝关节(P < 0.05),且左侧(ICC为0.870~0.964)踝关节重测的相关系数高于右侧(ICC为0.742~0.944)。提示老年人膝关节和踝关节位置觉重测的相关性良好,并且左侧踝关节的相关性高于右侧。

关键词: 本体感觉, 位置觉, 复位测试, 老年人, 膝关节, 踝关节

Abstract:

BACKGROUND: At home and abroad there are many studies of joint position in young people, but in older people, studies about test-retest reliability of joint position are lack.
OBJECTIVE: To determine the test-retest reliability of joint position in the different position of knee and ankle in older people.
METHODS: Ankle and knee joint position of 28 healthy older people was measured with passive replication test on the Biodex system 3 dynamometer. The absolute error angle of passive replication test was used to assess ankle position sense. The indicator of test-retest reliability of joint position was intraclass correlation coefficient (ICC).
RESULTS AND CONCLUSION: The test-retest reliability of joint position was modest in the different positions of both knee, and the values of ICC were from 0.851 to 0.973. The test-retest reliability of joint position was also modest in plantarflexion and dorsiflexion of both ankle, and the values of ICC were from 0.742 to 0.964. The absolute error angle of passive replication test in the left ankle was better than the right (P < 0.05); the test-retest reliability of the left ankle (ICC was from 0.870 to 0.964) was better than that of the right ankle (ICC was from 0.742 to 0.944). The test-retest reliability of joint position is good in the knee and ankle of older people, and the correlation of the left ankle is better than the right.

中图分类号: