中国组织工程研究 ›› 2010, Vol. 14 ›› Issue (35): 6583-6886.doi: 10.3969/j.issn.1673-8225.2010.35.031

• 骨与关节学术探讨 academic discussion of the bone and joint • 上一篇    下一篇

人工股骨头置换后的髋臼磨损

殷  辉   

  1. 桂林市全州县人民医院骨科,广西壮族自治区全州县  541500
  • 出版日期:2010-08-27 发布日期:2010-08-27
  • 作者简介:殷辉,男,1973年生,广西壮族自治区桂林市全州县人,汉族,2009年桂林医学院毕业,主治医师, 主要从事骨科临床的治疗与康复研究。 1175358300@qq.com

Acetabular wear following artificial femoral head replacement

Yin Hui   

  1. Department of Orthopedics, People’s Hospital of Quanzhou County, Quanzhou  541500, Guangxi Zhuang Autonomous Region, China
  • Online:2010-08-27 Published:2010-08-27
  • About author:Yin Hui, Attending physician, Department of Orthopedics, People’s Hospital of Quanzhou County, Quanzhou 541500, Guangxi Zhuang Autonomous Region, China 1175358300@qq.com

摘要:

目的:探讨不同类型人工股骨头的临床应用特征、术后髋臼磨损及其影响因素和处理对策。
方法:应用万方数据库和中国期刊全文数据库(CNKI),以“人工股骨头置换;全髋关节置换;髋臼磨损;临床意义;翻修技巧”等为检索词,检索1998/2010时限内与人工股骨头置换术后髋臼磨损有关的文献。排除重复研究或较陈旧文献。
结果:依据纳入排除标准共保留文献24篇。临床常用的人工股骨头按材料类型不同分为金属合金股骨头与陶瓷材料股骨头。金属合金股骨头价格低廉,耐腐蚀,易于置入,但并发症严重;陶瓷股骨头安全性及有效性较高,但经济投入较高,不易临床推广。从临床效果来看,陶瓷股骨头引起髋臼磨损的发生率要远远低于金属合金类。髋臼磨损的影响因素涉及生物材料、假体设计、手术技巧等方面,全髋关节翻修为髋臼磨损的最后对策,需注意翻修技巧等。
结论:陶瓷材料人工股骨头更适宜应用于人工股骨头置换术,其术后髋臼磨损的发生率较低。全髋关节翻修为髋臼磨损的最终治疗方案,其近、中期效果良好,长期效果有待进一步临床随访。

关键词: 人工股骨头置换, 全髋关节置换, 髋臼磨损, 临床意义, 翻修技巧

Abstract:

OBJECTIVE: To investigate the clinical features of artificial femoral head, influencing factors and treatment for acetabular wear following femoral head replacement.
METHODS: Literatures concerning acetabular wear following artificial femoral head replacement published between 1998 and 2010 were retrieved from Wanfang database and China Academic Journal databases using key words “artificial femoral head replacement, total hip replacement, acetabular wear, clinical significance, revision skill”. The repetitive studies or old literatures were excluded.
RESULTS: Totally 24 documents were included in the final analysis according to inclusive and exclusive criteria. The commonly used artificial femoral head comprised metal alloy and ceramic femoral heads. The metal alloy femoral head was characterized by low price, anti-corrosion, and easy implantation, however, it accompanied by server complications. Though the ceramic femoral head are good in safety and effectiveness, it is hard to apply due to high cost. In clinical results, the occurrence of acetabular wear caused by ceramic femoral head was notably lower than that of metal alloy. Selection of biological material, implant design, surgical techniques influence acetabular wear after replacement. Revision hip arthroplasty was the end solution for acetabular wear, and skills need pay more attention in hip revision. 
CONCLUSION: Ceramic femoral head is more suitable for femoral head replacement with low incidence of acetabular wear. Revision total hip replacement is the end solution for acetabular wear, which receives good results in near and mid-term, but the long-term effectiveness needs further exploration.

中图分类号: