远红外陶瓷微珠干预后肌肉物理3种特性指标的变化

何建伟1,2,郑汉山1,许  剑1,张  莹3   

  1. 1广州大学体育学院,广东省广州市  510006;2莆田学院体育学院,福建省莆田市  351100; 3浙江师范大学杭州幼儿师范学院,浙江省杭州市  310012
  • 收稿日期:2019-08-08 修回日期:2019-08-10 接受日期:2019-11-15 出版日期:2020-08-08 发布日期:2020-04-26
  • 作者简介:何建伟,男,1973年生,福建省莆田市人,汉族,博士,博士后,副教授,主要从事人体机能监控、运动性疲劳恢复、运动损伤防治与康复材料方面的研究。
  • 基金资助:
    广州大学引进人才科研启动项目-广州大学高水平大学建设专项-师资队伍建设项目(2900603999-290060344);福建省科技厅省自然科学基金项目(2016J01404);国家体育总局科技服务项目(2017HT008)

Changes in three physical indicators of the muscle after far-infrared ceramic microsphere intervention

He Jianwei1, 2, Zheng Hanshan1, Xu Jian1, Zhang Ying3   

  1. 1Physicial Education School of Guangzhou University, Guangzhou 510006, Guangdong Province, China; 2Physicial Education School of Putian University, Putian 351100, Fujian Province, China; 3Hangzhou Infant Normal College of Zhejiang Normal University, Hangzhou 310012, Zhejiang Province, China
  • Received:2019-08-08 Revised:2019-08-10 Accepted:2019-11-15 Online:2020-08-08 Published:2020-04-26
  • About author:He Jianwei, MD, Associate professor, Physicial Education School of Guangzhou University, Guangzhou 510006, Guangdong Province, China; Physicial Education School of Putian University, Putian 351100, Fujian Province, China
  • Supported by:
    the Guangzhou University Talents Introduction and Scientific Research Launching Project-Guangzhou University High-level University Construction Project-Faculty Construction Project, No. 2900603999-290060344; the Natural Science Foundation of Science and Technology Department of Fujian Province, No. 2016J01404; the Science and Technology Service Project of the State General Administration of Sports, No. 2017HT008

摘要:

文题释义:

肌肉伸展性:是指肌肉放松状态下的机械张力,描述肌肉处在动作和放松状态之间的恢复反复状况。伸展性高于正常值将会扰乱肌肉中的血流状况,因为肌肉中的血管越是收缩血液就越少回流到达肌肉,肌肉伸展性升高将导致疼痛、运动能力下降、过载和其他现象,但较低的伸展性又显示较低的运动能力和肌肉疲软无力,故此维持正常的肌肉伸展性意义重大。

肌肉弹性:是指肌肉工作后产生收缩形变回复到初始状态的能力,表现肌肉血流在运动中供给状况及所能提高运动速度的能力。运动中骨骼肌的血流供给是否充分表现在其外形在2次收缩的间隙能否迅速恢复到原来的初始状态,即骨骼肌必须具备良好的弹性才能保证良好的血流供给,弹性下降会明显加速肌肉疲劳,并且如果骨骼肌弹性有问题其运动速度必定也会受到制约。

背景:远红外光波治疗可促进血液快速流动、强化各组织间物质能量交换和促进骨骼肌微损伤快速恢复等能力,其中远红外陶瓷微珠为近年来运动理疗、康复领域一种崭新的功能康复材料。

目的:以远红外陶瓷微珠为干预手段,验证其对骨骼肌损伤后肌肉伸展性、肌肉硬度和肌肉弹性物理3特性指标的影响。

方法:选择年龄18-21岁各体育专业确诊为股后肌群损伤的男性在校学生为试验对象,通过筛选最终纳入20名受试者,随机数字表法分为2组,分别进行普通远红外治疗仪(对照组)与远红外陶瓷微珠干预治疗(试验组),每组10名受试者,连续干预2周。利用无创肌肉检测系统采集治疗前与治疗后第3,7,14天的股后肌肉伸展性、肌肉硬度和肌肉弹性数据。

结果与结论:①试验组治疗后3,7,14 d的肌肉伸展性大于治疗前(P < 0.05,P < 0.01),且治疗后14 d已恢复至健侧水平(P > 0.05);对照组仅治疗后14 d的肌肉伸展性大于治疗前(P < 0.05),但仍低于健侧(P < 0.05);试验组治疗后不同时间点的肌肉伸展性大于对照组(P < 0.05,P < 0.01);②试验组治疗后3,7,14 d的肌肉硬度大于治疗前(P < 0.05,P < 0.01),且治疗后14 d已恢复至健侧水平(P > 0.05);对照组仅治疗后14 d的肌肉硬度大于治疗前(P < 0.05),但仍低于健侧(P < 0.05);试验组治疗后不同时间点的肌肉硬度大于对照组(P < 0.05,P < 0.01);③试验组治疗后3,7,14 d的肌肉弹性大于治疗前(P < 0.05,P < 0.01),且治疗后14 d已恢复至健侧水平(P > 0.05);对照组仅治疗后14 d的肌肉弹性大于治疗前(P < 0.05),但仍低于健侧(P < 0.05);试验组治疗后不同时间点的肌肉弹性大于对照组(P < 0.05,P < 0.01);④结果表明,远红外陶瓷微珠干预可提高肌肉的伸展性、弹性,降低肌肉硬度,促进损伤肌肉的恢复。

ORCID: 0000-0002-9375-1940(何建伟)

中国组织工程研究杂志出版内容重点:生物材料;骨生物材料; 口腔生物材料; 纳米材料; 缓释材料; 材料相容性;组织工程

关键词: 远红外陶瓷微珠, 肌肉伸展性, 肌肉硬度, 肌肉衰减度, 量化评价, 物质能量交换, 骨骼肌微损伤, 康复材料

Abstract:

BACKGROUND: Far-infrared wave therapy can accelerate blood flow rapidly, strengthen the exchange of substance and energy among tissues, and promote the rapid recovery of musculoskeletal micro-injury. The far-infrared ceramic microsphere is a new functional rehabilitation material in the field of physical therapy and rehabilitation in recent years.

OBJECTIVE: To verify the therapeutic effectiveness of far-infrared ceramic microsphere intervention on muscle extensibility, stiffness, and elasticity after musculoskeletal injury.

METHODS: Male students aged 18-21 years who were diagnosed with posterior femoral muscle injury in each sports specialty were selected as test subjects. Twenty subjects were selected and randomly divided into two groups (n=10/group), and then underwent far-infrared therapeutic apparatus (control group) and far-infrared ceramic microsphere intervention treatment (trial group) for 2 consecutive weeks. A non-invasive muscle detection system was used to collect muscle extensibility, muscle stiffness, and muscle elasticity data before and 3, 7, and 14 days after treatment.

RESULTS AND CONCLUSION: (1) The muscle extensibility in the trial group at 3, 7, and 14 days after treatment was higher than that before treatment (P < 0.05, P < 0.01), and it had returned to the level of the healthy side at 14 days after treatment (P > 0.05). In the control group, the muscle extensibility at 14 days after treatment was higher than that before treatment (P < 0.05), but it was still lower than that of the healthy side (P < 0.05). The muscle extensibility at different time points in the trial group was higher than that in the control group (P < 0.05, P < 0.01). (2) The muscle stiffness in the trial group at 3, 7, and 14 days after treatment was higher than that before treatment (P < 0.05, P < 0.01), and at 14 days after treatment, it had returned to the level of the healthy side (P > 0.05). In the control group, the muscle stiffness at 14 days after treatment was higher than that before treatment (P < 0.05), but it was still lower than that of the healthy side (P < 0.05). The muscle stiffness at different time points in the trial group was higher than that in the control group (P < 0.05, P < 0.01). (3) The muscle elasticity in the trial group at 3, 7, and 14 days after treatment was higher than that before treatment (P < 0.05, P < 0.01), and at 14 days after treatment it had returned to the level of the healthy side (P > 0.05). In the control group, the muscle elasticity at 14 days after treatment was higher than that before treatment (P < 0.05), but it was still lower than that of the healthy side (P < 0.05). The muscle elasticity at different time points in the trial group was higher than that in the control group (P < 0.05, P < 0.01). (4) In summary, far-infrared ceramic microspheres can improve muscle extensibility and elasticity, reduce muscle stiffness and promote the recovery of muscle damage.

Key words: far-infrared ceramic microspheres, muscle extensibility, muscle stiffness, muscle attenuation, quantitative evaluation, exchange of substance and energy, muscle micro-injury, rehabilitation material