Chinese Journal of Tissue Engineering Research ›› 2017, Vol. 21 ›› Issue (31): 4963-4968.doi: 10.3969/j.issn.2095-4344.2017.31.008

Previous Articles     Next Articles

Comparison study of the effect of fusion and non-fusion fixation on the movement of injured lumbar spine

Song Hong-fang1, 2, Zhang Wen3, Zhang Qiang4, Liu Zhi-cheng1, 2   

  1. 1School of Biomedical Engineering, Capital Medical University, Beijing 100069, China; 2Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing 100069, China; 3Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing 100037, China; 4Department of Orthopedics, Beijing Ditan Hospital, Capital Medical University, Beijing 100015, China
  • Online:2017-11-08 Published:2017-12-01
  • Contact: Zhang Qiang, Chief physician, Department of Orthopedics, Beijing Ditan Hospital, Capital Medical University, Beijing 100015, China Liu Zhi-cheng, Professor, Doctoral supervisor, School of Biomedical Engineering, Capital Medical University, Beijing 100069, China; Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing 100069, China
  • About author:Song Hong-fang, M.D., Associate professor, School of Biomedical Engineering, Capital Medical University, Beijing 100069, China; Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing 100069, China
  • Supported by:

    the General Technology Research & Development Program of Beijing Municipal Education Commission, No. KM201410025012; the Key Basic-Clinical Cooperation Program of Capital Medical University, No. 16JL08

Abstract:

BACKGROUND: Degenerative change in lumbar spine is the natural physiological and pathological process with age increasing, which seriously affects the patients’ quality of life. Conventional surgical treatments may bring about some complications. Interspinous stabilization Coflex demonstrates good clinical outcomes, while there is lack of experimental evidence.

OBJECTIVE: To investigate the effect of fixation methods on the movement of lumbar vertebrae, and to provide reference for clinical operation from the aspect of biomechanics.
METHODS: Five fresh specimens of pig cadaveric lumbar spine were selected and divided into five groups: blank control group (group A), injury group (group B), L3-L4 Coflex fixed (group C), L3-L4 Coflex fixed plus decompression (group D), and L3-L4 intervertebral fusion fixed (group E). The biomechanical performance of the five lumbar specimens was tested in six loading directions of flexion/extension, left/right lateral bending, and left/right axial rotation driven by a robot system. The motion range of the operation segments (L3-L4) and the whole lumbar spine was observed by a multi-directional torque sensor combined with a three-dimensional motion capture system. Finally, the influence of lumber fixation methods on the spinal movement was explored.
RESULTS AND CONCLUSION: (1) For the range of three-dimensional angle at the operation segments (L3-L4), it was found that groups C and D were similar to group A, and groups B and E were quite different from group A. (2) Group E could restore the motion range of the injured segments, but the motion angle was much smaller than that in the groups C and D. (3) These results indicate that the motion angle of the injured spine treated with Coflex can restore to the normal state, with long-term stability. For unstable lumbar spine, interspinous Coflex is better than transforaminal lumbar interbody fusion, which can induce similar biomechanical properties to normal lumbar spine after operation.
 
中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱骨折;内固定;数字化骨科;组织工程

Key words: Biomechanics, Intervertebral Disk Degeneration, Internal Fixators

CLC Number: