人工股骨柄的力学研究现状

张岚峰1,葛世荣1,刘洪涛2   

  1. 中国矿业大学,1机电学院,2材料科学与工程学院,江苏省徐州市  221008
  • 收稿日期:2011-03-30 修回日期:2011-05-20 出版日期:2011-07-23 发布日期:2011-07-23
  • 作者简介:张岚峰★,男,1984年生,江苏省徐州市人,汉族,中国矿业大学在读硕士。 Zhanglanfeng20032004@yahoo.com.cn

Mechanical properties of artificial hip stems

Zhang Lan-feng1, Ge Shi-rong1, Liu Hong-tao2   

  1. 1Mechanical Electrical Engineering School, 2Materials Engineering and Science School, China University of Mining and Technology, Xuzhou  221116, Jiangsu Province, China
  • Received:2011-03-30 Revised:2011-05-20 Online:2011-07-23 Published:2011-07-23
  • About author:Zhang Lan-feng★, Studying for master’s degree, Mechanical Electrical Engineering School, China University of Mining and Technology, Xuzhou 221116, Jiangsu Province, China zhanglanfeng20032004@yahoo.com.cn

摘要:

背景:临床表明,全髋关节重建涉及假体、骨水泥和股骨整体的应力分布,针对减少各个组件的应力以减少置换关节失效风险研究有了很大的进展。
目的:对髋关节置换后各组件应力分布的研究现状及进展作一综述。
方法:应用计算机检索CNKI,EI Village和ELSEVER数据库中2001-01/2011-01关于髋关节置换和股骨柄应力的文章,在标题和摘要中以“股骨柄,应力,全髋关节置换”或“stem,prosthesis,stress,Total Hip Replacement”为检索词进行检索。入选34篇文献和2本书籍进行综述。
结果与结论:人工髋关节固定需亟待解决的关键问题是髋关节置换后各组件应力非均匀传递而引起的界面剪滞效应,并将最终导致界面松动失效。研究股骨-柄松动原因和增强股骨-柄界面的自锁能力,应是提高人工髋关节的稳定性和延长置换后髋关节寿命的发展方向。

关键词: 股骨柄, 生物力学, 应力, 有限元, 全髋关节置换

Abstract:

BACKGROUND: A total joint reconstruction is related to the stress distribution throughout the prosthesis, cement and femur. It is a significant progress for reducing the stresses in all components to minimize the risk of failure.
OBJECTIVE: To summarize the investigative situation and progression about stress distribution of all components after total hip replacement.
METHODS: The databases of CNKI, EI Village and ELSEVER (2001-01/2011-01) were retrieved to search the related articles about total hip replacement and stress distribution of stem. Putting stem, biomechanical, stress and finite element analysis as terms and then selecting some related articles. The keywords were “femoral stem, stress, total hip replacement” in Chinese and “stem, prosthesis, stress, total hip replacement” in English. Thirty-four articles and two books related to the stress distribution of stem were included.
RESULTS AND CONCLUSION: The fixture problems of hip prosthesis are summarized. It is interface shear lag effect resulted from the heterogeneity stress distribution of all components, which has an effect on the interfacial loosening failure. The further study on the reason of femur-stem loosening failure and reinforcement mechanism of interfacial bonding strength is put forward.

中图分类号: