Chinese Journal of Tissue Engineering Research ›› 2014, Vol. 18 ›› Issue (26): 4136-4141.doi: 10.3969/j.issn.2095-4344.2014.26.007

Previous Articles     Next Articles

Two different kinds of fixation materials in repair of distal clavicle fracture: stability of reconstruction

Cai Teng, Chen Yong   

  1. Second Department of Orthopedics, Tangshan Branch, Nanjing General Hospital of Nanjing Military Area Common of Chinese PLA, Nanjing 211131, Jiangsu Province, China
  • Online:2014-06-25 Published:2014-06-25
  • Contact: Chen Yong, Master, Associate chief physician, Second Department of Orthopedics, Tangshan Branch, Nanjing General Hospital of Nanjing Military Area Common of Chinese PLA, Nanjing 211131, Jiangsu Province, China
  • About author:Cai Teng, Master, Second Department of Orthopedics, Tangshan Branch, Nanjing General Hospital of Nanjing Military Area Common of Chinese PLA, Nanjing 211131, Jiangsu Province, China

Abstract:

BACKGROUND: For distal clavicle fracture, clavicular hook plate and Kirschner wire tension band were used in the clinic, but they cannot keep the dual function of stability and functional protection. However, the application of microporous locking plate of distal clavicle makes it possible to double efficacy.
OBJECTIVE: To compare and analyze the clinical outcomes of distal clavicle microporous locking plate and clavicular hook plate.
METHODS: From March 2011 to March 2013, 40 patients with distal clavicle fractures were involved in this study. They were divided into two groups with the voluntary principles: distal clavicle microporous locking plate group and clavicular hook plate group. We compared and observed perioperative indicators (operation time, blood loss, and hospitalization days), clinical curative effects (University of California at Los Angeles scoring system and American Shoulder and Elbow Surgeons Scale), the score of shoulder joint function (Karlsson standard) and the overall treatment (removed the plate and functional training costs).
RESULTS AND CONCLUSION: All patients successfully underwent surgery. At 1 year after surgery, internal fixators were taken out. Necessary relevant rehabilitation training was performed for more than 3 months. There was no significant difference in perioperative indicators (P > 0.05). However, clinical curative effects and the score of Karlsson shoulder joint function showed significant advantages in the microporous locking plate group (P < 0.05). Although the distal clavicle microporous locking plate material cost was high, but there was no significant statistic difference in the overall treatment for better protection shoulder function (P > 0.05). We draw the conclusion that distal clavicle microporous locking plate can effectively reconstruct the stability of the fracture site, and better retain the function of the joints at the same time.


中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱骨折;内固定;数字化骨科;组织工程


全文链接:

Key words: clavicle, fractures, bone, internal fixators, shoulder joint