Chinese Journal of Tissue Engineering Research ›› 2014, Vol. 18 ›› Issue (9): 1356-1361.doi: 10.3969/j.issn.2095-4344.2014.09.008

Previous Articles     Next Articles

Mechanical property of different cross-sectional area screws in middle and upper thoracic vertebral pedicle-rib complex

Xin Da-qi, Huo Hong-jun, Yang Xue-jun, Xing Wen-hua, Zhao Yan, Fu Yu, Zhu Yong, Li Feng   

  1. Department of Spine Surgery, Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot 010030, Inner Mongolia Autonomous Region, China
  • Online:2014-02-26 Published:2014-02-26
  • Contact: Huo Hong-jun, Master, Chief physician, Professor, Department of Spine Surgery, Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot 010030, Inner Mongolia Autonomous Region, China
  • About author:Xin Da-qi, Master, Attending physician, Department of Spine Surgery, Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot 010030, Inner Mongolia Autonomous Region, China
  • Supported by:

    the Science and Technology Ministry of Inner Mongolia Autonomous Region, No. 20090501

Abstract:

BACKGROUND: Due to the importance of pedicle adjacent structures, once the screw replacement appears a deviation, adjacent structures may be damaged, leading to extremely serious consequences. Although the security of screw placement in thoracic vertebral pedicle-rib complex is significantly greater than that of pedicle screws, the mechanics of the pedicle-rib complex at different cross-sectional areas of the screw are rarely reported.
OBJECTIVE: To observe mechanical property of different cross-sectional area screws in the middle and upper thoracic vertebral pedicle-rib complex.
METHODS: Five specimens of adult cadaveric thoracic spine (T1-T10) and adjacent rib segment (50-60 mm long) were used. The bone density of specimens was measured using difunctional bone density testing machine, and osteoporotic vertebral body was excluded. The position of the screws was detected with CT images. The maximal withdrawal force of the pedicle screw was measured with biomechanical force test machine.
RESULTS AND CONCLUSION: Thirty-eight specimens at normal bone density were implanted with 25 screws (5.5 mm), 25 screws (6.0 mm) and 26 screws (6.5 mm). Because the pedicle screws destroyed the pedicle-rib complex and perforated the vertebral body, we finally obtained the withdrawal force of 68 screws. The axial  withdrawal force of pedicle screws at different diameters was (812.36±147.22) N, (868.64±160.48) N and (946.48±157.58) N, respectively. There were significant differences between the 5.5 mm screws and the 6.5 mm screws (P < 0.05). Experimental findings indicate that, the pedicle screws (diameter > 5.5 mm) are suitable in the middle and upper thoracic vertebral pedicle-rib complex due to strong internal fixation and clinical requirement.


中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱骨折;内固定;数字化骨科;组织工程


全文链接:

Key words: spine, thoracic vertebrae, internal fixator, rib, biomechanics

CLC Number: