Chinese Journal of Tissue Engineering Research ›› 2013, Vol. 17 ›› Issue (22): 4042-4046.doi: 10.3969/j.issn.2095-4344.2013.22.008

Previous Articles     Next Articles

Digital measurement of the vertebral body during lateral anterior internal fixation of middle and lower thoracic vertebrae

Li Xiao-he, Li Zhi-jun, Wang Hai-yan, Wang Jian-wei, Ji Xiao-jun   

  1. Department of Anatomy, Basic Medical College of Inner Mongolia Medical University, Hohhot  010059, Inner Mongolia Autonomous Region, China
  • Online:2013-05-28 Published:2013-05-28
  • Contact: Wang Hai-yan, Master, Associate professor, Department of Anatomy, Basic Medical College of Inner Mongolia Medical University, Hohhot 010059, Inner Mongolia Autonomous Region, China lixiaohe12@hotmail.com
  • About author:Li Xiao-he☆, M.D., Associate professor, Department of Anatomy, Basic Medical College of Inner Mongolia Medical University, Hohhot 010059, Inner Mongolia Autonomous Region, China 798242742@qq.com
  • Supported by:

    Doctoral Starting Foundation of Inner Mongolia Medical University, No.BSJJ2011007*; Natural Science Foundation of Inner Mongolia Autonomous Region, No.2012MS1117*

Abstract:

BACKGROUND: There are many reports on the entrance point of adult vertebral screw, but most of the reports are the general description. Because of the differences in races and segments, the shape of vertebral body is various, and the choice of screw placement position is also varied. 
OBJECTIVE: To construct the three-dimensional model of lower thoracic vertebra through CT scanning combined with reverse engineering software, and to digital measure the correlated anatomic CT data of the lateral anterior middle and lower thoracic vertebra of Chinese adults. 
METHODS: The CT primary data of non-spinal disorders cases were collected and the data were used for the establishment of three-dimensional model of complete middle and lower thoracic vertebra (T4-T12) of Chinese people with Mimics software. The coronal plane left and right edge height, midsagittal anterior, median and posterior edge height, sagittal diameter and transverse diameter of the upper vertebral endplate and the lower vertebral endplate were measured.
RESULTS AND CONCLUSION: The sagittal diameter and transverse diameter of the upper and lower vertebral endplates were gradually increased with the increasing vertebral sequence. The vertebral screw selection had certain regularity when placing in the anterior middle and lower thoracic vertebra; because the transverse diameter of vertebra bodies was always bigger than sagittal diameter for 3.0-4.0 mm, bone graft should be shaped into laterigrade cuboid (the length should be larger than width for 3.0-4.0 mm). The clinical lateral anterior approach internal fixation of middle and lower thoracic vertebra should refer to the data above.

Key words: bone and joint implants, spinal implants, middle and lower thoracic vertebrae, lateral anterior , internal fixation, CT data, Mimics software, three-dimensional model, digital anatomy, provincial grants-supported paper

CLC Number: