Chinese Journal of Tissue Engineering Research ›› 2015, Vol. 19 ›› Issue (12): 1812-1816.doi: 10.3969/j.issn.2095-4344.2015.12.002

Previous Articles     Next Articles

Stainless steel locking plate implantation for fractures of the proximal humerus: restoration of joint function and incidence of adverse events

Zhou Xue-feng, Zhou Jia-ning, Ma Hua-song, Bai Ke-wen, Peng Jun, Bao Lei, Wang Meng, Ma Xiao-ming, Lu Ming   

  1. Department of Orthopedics, the 306th Hospital of PLA, Beijing 100101, China
  • Revised:2014-12-30 Online:2015-03-19 Published:2015-03-19
  • Contact: Ma Hua-song, M.D., Chief physician, Professor, Department of Orthopedics, the 306th Hospital of PLA, Beijing 100101, China
  • About author:Zhou Xue-feng, Master, Associate chief physician, Department of Orthopedics, the 306th Hospital of PLA, Beijing 100101, China

Abstract:

BACKGROUND: During ordinary plate fixation, the soft tissues around the fracture of the proximal humerus are nearly stripped to impact blood supply, and moreover, an ordinary steel plate cannot meet with the fixed requirements for severe osteoporosis, large bone defects and comminuted fractures.
OBJECTIVE: To observe the functional recovery and complications in middle-aged patients with proximal humeral fractures undergoing stainless steel locking plate implantation.
METHODS: From March 2011 to March 2014, 48 patients with proximal humeral fractures were treated in the 306th Hospital of PLA, including 20 males and 28 females, with an average age of 58 years. Of the 48 cases, there were 9 cases of Neer 2 fractures, 26 cases of Neer 3 fractures, and 13 cases of Neer 4 cases, all of which belonged to closed injuries. All the patients were subject to locking plate implantation for repair of fractures of the proximal humerus, and evaluated based on Neer scores.
RESULTS AND CONCLUSION: The 48 patients were followed up for 6-17 years, and the mean healing time was (15.3±1.2) weeks. At the last follow-up, the Neer scores were excellent in 12 cases, good in 22 cases, fair in 11 cases and poor in 3 cases, with an excellent-good rate of 71%. After internal fixation, there was one case of  soft tissue infection, two cases of traumatic arthritis, and no bone ununion and osteomyelitis. These findings suggest that the stainless steel locking plate implantation for repair of fractures of the proximal humerus can achieve a good anatomic reduction under minimally invasive conditions and produce a stable rehabilitation environment for the soft tissue around the shoulder joint by internal fixation. Hence, the factures can recover faster with less complications. The stainless steel locking plate implantation can obtain good achievements in the repair of proximal humeral fractures of Neer 2, 3 as well as Neer 4 in young patients with good bone quality.


中国组织工程研究杂志出版内容重点:生物材料;骨生物材料; 口腔生物材料; 纳米材料; 缓释材料; 材料相容性;组织工程


全文链接:

Key words: Shoulder Fractures, Humerus, Fracture Fixation, Internal, Recovery of Function

CLC Number: