The clinical application of absorbable internal fixation system in maxillofacial fractures: systematic review and Meta-analysis 

Liu Hang-hang1, Wu Chen-zhou1, Pan Wei-yi1, Su Zhi-fei1, Duan Ze-xi1, Shi Long1, Li Chun-jie1, 2   

  1. 1State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, Sichuan Province, China; 2Department of Head and Neck Oncology, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan Province, China
  • Received:2015-10-23 Online:2015-12-17 Published:2015-12-17
  • Contact: Li Chun-jie, Lecturer, State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, Sichuan Province, China; Department of Head and Neck Oncology, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan Province, China
  • About author:Liu Hang-hang, State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, Sichuan Province, China Wu Chen-zhou, State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, Sichuan Province, China Liu Hang-hang and Wu Chen-zhou contributed equally to this work.
  • Supported by:

    the Scientific Research Foundation for Young Teachers in Sichuan University in 2014, No. 2014SCU11032

Abstract:

BACKGROUND: There are numerous clinical studies on comparing absorbable internal fixation system and titanium metal internal fixation system in maxillofacial fractures; however, the systematic reviews and Meta-analysis in this field are rare.
OBJECTIVE: To compare the clinical effect of absorbable internal fixation system and titanium internal fixation system in maxillofacial fractures through systematic review and Meta-analysis.
MATERIALS AND METHODS: The randomized controlled trials and controlled clinical trials regarding the application of absorbable internal fixation system and titanium internal fixation system in maxillofacial fractures were electronically retrieved from Medline, Embase, the Cochrane Central Register of Controlled Trials, China Biology Medicine disc, and China Academic Journal Network Publishing Database using the keywords. Meta-analysis was conducted using Revman 5.3 software.
RESULTS AND CONCLUSION: Thirteen clinical studies were included, and totally 1 718 patients were involved. The Meta-analysis results showed that the removal rate of implants in the absorbable internal fixation system group was significantly lower than that in the titanium internal fixation group (P=0.000 2); there were no significant differences in the healing rate of fracture I stage, the incidence of insufficient fixation in fracture site and the incidence of long-term complications between these two groups. These results demonstrate that the efficiency and safety of absorbable internal fixation system in maxillofacial fracture is satisfactory, and can reduce the proportion of secondary surgical removal of the implant. More randomized controlled trials should be conducted to confirm this conclusion.
 