Chinese Journal of Tissue Engineering Research ›› 2010, Vol. 14 ›› Issue (48): 8966-8969.doi: 10.3969/j.issn.1673-8225.2010.48.010

Previous Articles     Next Articles

Anatomical observation of transforaminal lumbar interbody fusion using single anatomical threaded cage insertion

Wang Zhao-jie, An Rong-ze, Wang Ke-qiang, Qi Xin-wen, Yu Hua-wei   

  1. Department of Orthopedics, Fifth Affiliated (Zhuhai) Hospital of Zunyi Medical College, Zhuhai  519100, Guangdong Province, China
  • Online:2010-11-26 Published:2010-11-26
  • Contact: An Rong-ze, Chief physician, Professor, Master’s supervisor, Department of Orthopedics, Fifth Affiliated (Zhuhai) Hospital of Zunyi Medical College, Zhuhai 519100, Guangdong Province, China wangzhaojie@sohu.com
  • About author:Wang Zhao-jie☆, Doctor, Chief physician, Master’s supervisor, Department of Orthopedics, Fifth Affiliated (Zhuhai) Hospital of Zunyi Medical College, Zhuhai 519100, Guangdong Province, China
  • Supported by:

    the Key Medical Construction Foundation of Zhuhai, No. [2008]80

Abstract:

BACKGROUND: The surgical instruments of transforaminal lumbar interbody fusion (TLIF) have been shown to be designed according to the body of the Western. Therefore, it is necessary to explore the related anatomy technique.
OBJECTIVE: To measure the lumbar intervertebral foramen and the anatomical data associated with TLIF.
METHODS: Intervertebral foramen width, length, and height of 14 normal adult cadavers lumbar spine were observed; the distance from structure of the lumbar spine to the midst sagittal plane from L3 to L5 was measured as well.
RESULTS AND CONCLUSION: Lumbar intervertebral foramen width gradually become smaller from L1 to L5; the height was gradually increased from L1 to L4, and L5 was slightly smaller than L4; the height was significantly greater than the width from L1 to L5 (P < 0.01); the length of intervertebral foramen was gradually increased from L1 to L5 as well (P < 0.05). The distance from the lateral margin of the pars interarticularis to the midst sagittal plane from L3 to L5 was gradually increased, and the distance from inferior articular process to the midst sagittal plane from L3 to L5 was increased as well. There was no significant difference in gender or two sides (P > 0.05). Results showed that 9-14 mm single posterolateral threaded fusion cage can be inserted by intervertebral foramen approach in Chinese. Single cage implant do not pull dura or nerve roots, thereby preventing spinal cord and nerve root injury.

CLC Number: