Ma De-chun1, Li Tian-hua1, Dong Ke-xin1, Zhao Chun-yu2, Li Lei3   

  1. 1 Department of Orthopedics, Second Affiliated Hospital of Jilin University, Changchun  130041, Jilin Province, China; 2 Medicare Office, Changchun Hospital for Infectious Diseases, Changchun  130041, Jilin Province, China; 3 Department of Vascular Surgery, Jilin Qianwei Hospital, Changchun  130041, Jilin Province, China
  • Online:2013-12-17 Published:2013-12-17
  • Contact: Li Tian-hua, Department of Orthopedics, Second Affiliated Hospital of Jilin University, Changchun 130041, Jilin Province, China
  • About author:Ma De-chun, Department of Orthopedics, Second Affiliated Hospital of Jilin University, Changchun 130041, Jilin Province, China 286582787@qq.com

Abstract:

BACKGROUND: Early clinical application of non-biological materials (bone cement) for treatment of hip joint is ineffective, due to the large fixed range, long fixation time, as well as aging and rupture of bone cement interface causing complications such as prosthetic loosening. Thus, postoperative range of motion of the hip joint can be affected to some degree.
OBJECTIVE: To investigate the methods and progress of biological and non-biological materials for total hip replacement and to assess the features and clinical application of different hip prostheses.
METHODS: A computer-based search of PubMed and CNKI was performed by the first author to retrieve articles related to biological materials and tissue-engineered hip joint using the keywords of “carpal bone, fracture ununited” in the title and abstract. The keywords were limited to Chinese and English.
RESULTS AND CONCLUSION: Biological materials for internal fixation have good wear resistance, corrosion resistance and biocompatibility. Currently, the combination of metal joint head and polyethylene acetabulum with ultrahigh molecular weight is the most commonly used in hip replacement. However, the metal joint head exhibits an elastic modulus far from the human skeleton, resulting in stress shielding effects which are easy to cause prosthetic loosening and instability. Bio-inert ceramics has high in vivo stability and good mechanical strength; and bioactive ceramics has bone conduction characteristics and performance of the living bone integration. Composite prosthesis, because of adjustable elastic modulus and sufficient mechanical strength, shows the mechanical properties close to the human bone and has been gradually noticed. However, there is a lack of ideal prostheses with good biocompatibility and biomechanics. Therefore, hip design and manufacturing processes should be improved to elevate wear resistance and mechanical properties, to enhance the binding between prosthesis and the host bone, and to reduce stress shielding in order to improve the biocompatibility of the implant with the host, and extend the prosthetic life.


中国组织工程研究杂志出版内容重点:生物材料;骨生物材料; 口腔生物材料; 纳米材料; 缓释材料; 材料相容性;组织工程


全文链接:

Key words: biocompatible materials, hip joint, arthroplasty, replacement, hip, review