中国组织工程研究 ›› 2015, Vol. 19 ›› Issue (25): 4059-4063.doi: 10.3969/j.issn.2095-4344.2015.25.024

• 材料生物相容性 material biocompatibility • 上一篇    下一篇

几丁糖与聚乳酸合成生物材料修复周围神经缺损

黄永旺1,范学政2   

  1. 1桂林医学院附属医院神经外科,广西壮族自治区桂林市  541000;
    2广西中医药大学附属瑞康医院神经外科,广西壮族自治区南宁市  530000
  • 出版日期:2015-06-18 发布日期:2015-06-18
  • 通讯作者: 范学政,博士,主任医师,广西中医药大学附属瑞康医院神经外科,广西壮族自治区南宁市 530000
  • 作者简介:黄永旺,男,1980年生,汉族,广西壮族自治区北海市人,硕士,主治医师,主要从事脑血管病研究。
  • 基金资助:

    广西壮族自治区卫生厅课题(Z2013245)“醒脑静经TLR4/NF-κB信号通路干预大鼠脑出血后炎症反应和神经元凋亡的实验研究”

Chitosan/polylactic acid complex for repair of peripheral nerve defects

Huang Yong-wang1, Fan Xue-zheng2   

  1. 1Department of Neurosurgery, Affiliated Hospital of Guilin Medical University, Guilin 541000, Guangxi Zhuang Autonomous Region, China;
    2Department of Neurosurgery, Ruikang Hospital, Guangxi University of Chinese Medicine, Nanning 530000, Guangxi Zhuang Autonomous Region, China
  • Online:2015-06-18 Published:2015-06-18
  • Contact: Fan Xue-zheng, M.D., Chief physician, Department of Neurosurgery, Ruikang Hospital, Guangxi University of Chinese Medicine, Nanning 530000, Guangxi Zhuang Autonomous Region, China
  • About author:Huang Yong-wang, Master, Attending physician, Department of Neurosurgery, Affiliated Hospital of Guilin Medical University, Guilin 541000, Guangxi Zhuang Autonomous Region, China
  • Supported by:

    the Project of Health Department of Guangxi Zhuang Autonomous Region, No. Z2013245

摘要:

背景:单纯几丁糖材料制成的神经导管机械强度较差,易于塌陷,不利于再生神经的生长。
目的:观察几丁糖与聚乳酸复合物修复大鼠周围神经缺损的可行性。
方法:取30只SD大鼠,制作单侧坐骨神经缺损模型,随机均分为3组,分别采用自体神经、硅胶导管及几丁糖与聚乳酸复合导管修复神经缺损,修复后12周,观察桥接神经外观、表面粘连情况及有无神经瘤生成等,检测大鼠神经传导速度、动作电位波幅及潜伏期,苏木精-伊红染色观察坐骨神经桥接物中段神经再生轴突数量及再生神经横截面积,称量大鼠完整小腿三头肌湿质量。
结果与结论:修复后12周,3组再生神经均通过5 mm神经缺损间隙,硅胶管组形成神经瘤,其余两组均未出现神经瘤;自体神经组再生神经直径大于几丁糖-聚乳酸组、硅胶管组(P < 0.05),几丁糖-聚乳酸组再生神经直径大于硅胶管组(P < 0.05);几丁糖-聚乳酸组、自体神经组可见排列整齐的高密度再生轴突,再生轴突数量多于硅胶管组(P < 0.05),且神经传导速度、动作电位波幅、小腿三头肌湿质量显著大于硅胶管组(P < 0.05),潜伏期低于硅胶管组(P < 0.05)。表明几丁糖-聚乳酸复合导管可促进缺损周围神经的再生。

 中国组织工程研究杂志出版内容重点:生物材料;骨生物材料; 口腔生物材料; 纳米材料; 缓释材料; 材料相容性;组织工程

关键词: 生物材料, 材料相容性, 几丁糖, 聚乳酸, 硅胶管, 周围神经缺损, 神经导管

Abstract:

BACKGROUND: The mechanical strength of nerve conduits made by chitosan is poor and easy to collapse, which is not conducive to the nerve regeneration.
OBJECTIVE: To explore the feasibility of chitosan/polylactic acid complex in the repair of peripheral nerve defects in rats.
METHODS: Thirty Sprague-Dawley rats were enrolled to establish models of unilateral sciatic nerve defects, and then randomly divided into three groups: autologous nerve, silicone catheter and chitosan/polylactic acid complex were used for defect repair in the three groups, respectively. At 12 weeks after operation, appearance of bridged nerves, surface adhesion, formation of neuroma were observed; nerve conduction velocity, action potential amplitude and latent period were determined; hematoxylin-eosin staining was performed to observe the number of regenerated axons and area of regenerated nerves; wet weight of the complete triceps surae was measured.
RESULTS AND CONCLUSION: At 12 weeks after repair, the regenerated nerves in the three groups all passed 
through the 5 mm nerve defect gaps, and neuroma only formed in the silicone catheter group. The diameter of regenerated nerves in the three groups was ranked as follows: autologous nerve group > chitosan/polylactic acid group > silicone catheter group (P < 0.05). High-density regenerated axons neatly arranged in the autologous nerve and chitosan/polylactic acid groups, and the number of regenerated axons was higher than that in the silicone catheter group (P < 0.05). Moreover, the nerve conduction velocity, action potential amplitude and wet weight of the complete triceps surae were significantly higher in the autologous nerve and chitosan/polylactic acid groups than in the silicone catheter group (P < 0.05), but the latent period was lower than that in the silicone catheter group (P < 0.05). These findings indicate that the chitosan/polylactic acid conduits can promote peripheral nerve regeneration.

Key words: Biocompatible Materials, Peripheral Nerves, Sciatic Nerve

中图分类号: